When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
FLUKE 117 117C HAVC VoltAlert Backlight Electrician's Multimeter
Please note that the outer package contains Chinese characters.
The Fluke 117C is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117C includes integrated non-contact voltage detection to help get the job done faster. The new case is designed for Fluke 117C.Feature:VoltAlert™ technology for non-contact voltage detectionAutoVolt automatic ac/dc voltage selectionLow input impedance: helps prevent false readings due to ghost voltageLarge white LED backlight to work in poorly lit areasTrue-rms for accurate measurements on non-linear loadsMeasures 10 A (20 A overload for 30-seconds)Resistance, continuity, frequency and capacitanceMin/Max/Average with elapsed time to record signal fluctuationsCompact ergonomic design for one-handed operationCompatible with optional magnetic hanger (ToolPak™) for hands free operationCAT III 600 V safety ratedSpecification:
Accuracy Specifications
DC millivolts
Range:
600.0 mV
Resolution:
0.1 mV
Accuracy:
± ([% of reading] + [counts]): 0.5% + 2
DC V / 0.001 V
Range/Resolution:
60.00 V / 0.01 V
Range/Resolution:
600.00 V / 0.1 V
Accuracy:
± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:
600.0 V
Resolution:
0.1 V
Accuracy:
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC mV
Resolution:
0.1 mV
Accuracy:
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC V / 0.001 V
Range/Resolution:
60.00 V / 0.01 V
Range/Resolution:
600.0 V / 0.1 V
Accuracy:
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 Ω
Resolution:
1 Ω
Accuracy:
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or Ω / 0.1 Ω
Range/Resolution:
6.000 kΩ / 0.001 kΩ
Range/Resolution:
60.00 kΩ / 0.01 kΩ
Range/Resolution:
600.0 kΩ / 0.1 kΩ
Range/Resolution:
6.000 MΩ / 0.001 MΩ
Accuracy:
0.9 % + 1
Range/Resolution:
40.00 MΩ / 0.01 MΩ
Accuracy:
1.5 % + 2
Diode V / 0.001 V
Accuracy:
0.9% + nF / 1 nF
Range/Resolution:
10.00 μF / 0.01 μF
Range/Resolution:
100.0 μF / 0.1 μF
Range/Resolution:
9999 μF / 1 μF
Range/Resolution:
100 μF to 1000 μF
Accuracy:
1.9% + 2
Range/Resolution:
> 1000 μF
Accuracy:
5% + 20%
LoZ capacitance
Range:
1 nF to 500 μF
Accuracy:
10% + 2 typical
AC amps true-rms (45 Hz to 500 Hz)
Range/Resolution:
6.000 A / 0.001 A
Range/Resolution:
10.00 A / 0.01 A
Accuracy:
1.5%+3 20 A continuous overload for 30 seconds max
DC A / 0.001 A
Range/Resolution:
10.00 A / 0.01 A
Accuracy:
1.0% + 3 20 A continuous overload for 30 seconds max
Hz (V or A Hz / 0.01 Hz
Range/Resolution:
999.99 Hz / 0.1 Hz
Range/Resolution:
9.999 Hz / 0.001 Hz
Range/Resolution:
50.00 Hz / 0.01 Hz
Accuracy:
0.1% + 2
Closer Look: Package Including:1 X Fluke 117C Multimeter1 X Set of Test Leads TL751 X User ManualPayment
- We accept bothPaypalandCredit card(what no Paypal account needed). They are easy and safety what you need is only a credit card.
- Please make payment within5 dayswhen you offer or sale ended.
- PleaseDO NOToffer if you areNOTintend to buy. For unpaid item more than 5 days,Unpaid dispute & the Negative responsewill be filed to for the non payable buyers.
Shipping & Delivery
- All products will be sent within48 hoursafter your Paymet received except Sunday (GMT+8).
Contact Us
- Welcome!! Please readALL POLICIESof us before your purchase.
- If you have additional questions or concerns about this item, please contact us via email.We will response the most E-mail within24hours(9:00-18:00 GMT+8 Monday-Friday).
- They Message through could be marked asSpamsometimes. Please check Spam folder of your Email Box first, if you haven't received our response after 72 hours.
Return Policy